Buderus WPT 270/2 I-S

Buderus WPT 270/2 I-S Heat Pump Water Heater Instruction Manual

Model: WPT 270/2 I-S

1. Gwybodaeth Diogelwch

Pwysig: Read all instructions carefully before installation, operation, or maintenance of the Buderus WPT 270/2 I-S Heat Pump Water Heater. Failure to follow these instructions could result in property damage, personal injury, or death.

  • Rhaid i dechnegydd cymwysedig berfformio'r gosodiad a'r gwasanaeth.
  • Sicrhewch fod yr uned wedi'i seilio'n iawn i atal sioc drydanol.
  • Do not operate the unit if any part is damaged or malfunctioning.
  • Cadwch ddeunyddiau fflamadwy i ffwrdd o'r gwresogydd dŵr.
  • Sicrhewch fod digon o awyru o amgylch yr uned.
  • The appliance must be installed in a frost-free environment.
  • Maximum operating temperature for stored hot water is 80 °C. Maximum operating temperature for heated water is 110 °C.
  • Maximum operating pressure for stored hot water side is 10 bar. Maximum operating pressure for heated water side is 6 bar.

2. Cynnyrch Drosview

The Buderus Logafix WPT 270/2 I-S is a highly efficient heat pump water heater designed to utilize up to 70% free environmental energy from ambient air and appliance waste heat for water heating. This unit offers flexible installation options and advanced features for domestic hot water supply.

Buderus WPT 270/2 I-S Heat Pump Water Heater

Figure 1: Buderus WPT 270/2 I-S Heat Pump Water Heater. This image shows the cylindrical white unit with control panel and various connections.

Nodweddion Allweddol:

  • Efficient hot water generation using ambient air.
  • Flexible installation: standalone or integrated with central heating/solar systems.
  • Removable heat pump section for easier installation.
  • Advanced control with illuminated display and multiple time programs.
  • Additional functions: basement dehumidification, ventilation, and air cooling.
  • Corrosion-resistant Buderus thermoglaze Duoclean plus and magnesium anode.
  • High energy efficiency (95%) and COP (3.2 according to EN16147).

3. Gosod a Gosod

Proper installation is crucial for the safe and efficient operation of your Buderus WPT 270/2 I-S. This section provides general guidelines; always refer to local regulations and consult a qualified installer.

3.1 Dewis Safle

  • Lleoliad: The unit should be installed in a frost-free basement or utility room.
  • Tymheredd aer amgylchynol: The temperature of the intake air must be between +5 °C and +35 °C.
  • Awyru: Ensure adequate air circulation for optimal heat pump performance.
  • Gofod: Allow sufficient space around the unit for maintenance and service.

3.2 Cysylltiad Trydanol

  • The unit requires a 230 V/50 Hz electrical connection.
  • The electric heating element is 2 kW.
  • All electrical work must comply with local codes and be performed by a certified electrician.

3.3 Cysylltiadau Dŵr

  • Connect the cold water inlet and hot water outlet according to the markings on the unit.
  • Gwnewch yn siŵr bod yr holl gysylltiadau'n dal dŵr.
  • The unit includes a smooth tube heat exchanger for optional connection to a solar system or boiler.

3.4 Air Duct System (Optional)

  • The WPT 270/2 I-S can be connected to an air duct system.
  • It features two DN160 supports for optional duct system connection.
  • This allows for additional functions such as basement dehumidification, ventilation, and air cooling.

3.5 Cychwyn Cychwynnol

  • After all connections are made and checked, fill the water tank completely before switching on the power.
  • Follow the on-screen prompts on the control panel for initial configuration.

4. Cyfarwyddiadau Gweithredu

The Buderus WPT 270/2 I-S features an intuitive control panel with an illuminated display for easy operation.

4.1 Panel Rheoli

The illuminated display provides information on current status, temperature settings, and operational modes. Use the navigation buttons to access menus and adjust settings.

4.2 Gosodiad Tymheredd

  • Gweithrediad Pwmp Gwres: Hot water temperature can be set up to 60 °C using the heat pump.
  • Elfen Gwresogi Trydan: For higher temperatures, the integrated electric heating element can raise the water temperature up to 70 °C.
  • Adjust the desired temperature via the control panel settings.

4.3 Time Programs

  • The unit supports multiple time programs, allowing you to schedule hot water production to match your daily routine and optimize energy consumption.
  • Refer to the control panel menu for setting up and managing time programs.

4.4 Thermal Disinfection

The WPT 270/2 I-S includes a thermal disinfection function to prevent bacterial growth (e.g., Legionella). This function periodically heats the water to a high temperature. Consult the manual for activation and scheduling of this feature.

4.5 Additional Functions (with Air Duct System)

If connected to an air duct system, the unit can provide:

  • Basement Dehumidification: Helps reduce humidity levels in the basement.
  • Swyddogaeth Awyru: Improves air circulation.
  • Air Cooling: Provides a degree of air cooling in the connected space.

5. cynnal

Regular maintenance ensures the longevity and efficient operation of your Buderus WPT 270/2 I-S. Always disconnect power before performing any maintenance.

5.1 Amddiffyn rhag Cyrydiad

  • The internal surfaces in contact with hot water are protected with Buderus thermoglaze Duoclean plus, which is corrosion-resistant according to DIN 4753-3.
  • A magnesium anode provides additional cathodic corrosion protection. This anode should be inspected periodically (e.g., annually) by a qualified technician and replaced if significantly depleted.

5.2 Glanhau ac Arolygu Cyffredinol

  • Keep the exterior of the unit clean. Use a soft, damp brethyn. Peidiwch â defnyddio glanhawyr sgraffiniol.
  • Gwiriwch yn rheolaidd am unrhyw ollyngiadau o amgylch y cysylltiadau.
  • Ensure that the air intake and exhaust vents (if applicable) are free from obstructions.
  • It is recommended to have the unit professionally inspected and serviced annually.

6. Datrys Problemau

This section provides basic troubleshooting steps for common issues. For more complex problems, contact a qualified service technician.

6.1 No Hot Water / Insufficient Hot Water

  • Gwiriwch y cyflenwad pŵer: Gwnewch yn siŵr bod yr uned wedi'i phlygio i mewn ac nad yw'r torrwr cylched wedi tripio.
  • Gwiriwch y Gosodiadau Tymheredd: Verify the desired temperature is set correctly on the control panel.
  • Time Programs: Ensure no time program is preventing hot water production.
  • Llif aer: Check if the air intake or exhaust is blocked.
  • Codau Gwall: Look for any error messages on the display and consult the full manual for their meaning.

6.2 Sŵn Anarferol

  • Minor operational noises are normal.
  • If you hear loud or unusual noises, turn off the unit and contact a service technician.

6.3 Gollyngiadau

  • Immediately turn off the water supply and power to the unit.
  • Nodwch ffynhonnell y gollyngiad.
  • Contact a qualified plumber or service technician.

7. manylebau

NodweddGwerth
GwneuthurwrBuderus
Rhif Rhan7736501465
ModelWPT 270/2 I-S
Cyfrol260 litr
Cyftage230 Folt
Maximum Pressure (Hot Water Side)10 Bar
Maximum Pressure (Heated Water Side)6 Bar
Diamedr700 Milimetr
Pwysau125 Cilogram
Heating Power / Output2.0 kW
Heat Exchange Surface1.3 m²
Elfen Gwresogi Trydan2 kW
COP (according to EN16147)3.2
Effeithlonrwydd Ynni95%
Dyddiad Cyntaf Ar GaelIonawr 15, 2020

8. Gwarant a Chefnogaeth

For detailed warranty information, please refer to the warranty card included with your product or visit the official Buderus website. In case of technical issues, service requests, or questions not covered in this manual, please contact Buderus customer support or your authorized dealer.

Gwneuthurwr: Buderus

Websafle: www.buderus.com (neu ranbarthol berthnasol websafle)

© 2023 Buderus. All rights reserved. Information subject to change without notice.

Ask a question about this manual