Bogen BG-NR100 Night Ringer device with connection terminals
The Bogen BG-NR100 Night Ringer is a compact device designed to provide an audible ring signal for paging systems. It responds to standard 90V telephone ring signals or external contact closures, producing a distinct dual-frequency electronic ringer tone. This unit is ideal for environments where telephone ring signals need to be amplified or integrated into a public address system, automatically muting background music during a ring event.

The Bogen BG-NR100 Night Ringer is an essential component for integrating telephone ringing into a paging or public address system. It is engineered to detect incoming telephone ring signals or external contact closures and generate a loud, clear electronic ringer tone. Its compact design and low current draw make it an efficient and reliable solution for various commercial and industrial applications.

1.2 Nodweddion Allweddol

  • Responds to 90V ring signals or external contact closures.
  • Produces a clear dual-frequency electronic ringer tone.
  • Easily connects to any standard paging system.
  • Automatically mutes background music while ringing.
  • Features a 0-level ringer volume control for adjustable output.
  • Compact size for convenient installation.
  • Low current draw for energy efficiency.

2. Gwybodaeth Diogelwch

Please read all safety instructions carefully before installing or operating the Bogen BG-NR100 Night Ringer. Failure to follow these instructions may result in electric shock, fire, or other hazards.

2.1 Rhagofalon Diogelwch Cyffredinol

  • Peidiwch â gwneud y ddyfais hon yn agored i law neu leithder.
  • Peidiwch â rhwystro unrhyw agoriadau awyru.
  • Peidiwch â gosod ger unrhyw ffynonellau gwres fel rheiddiaduron, cofrestrau gwres, stofiau, neu gyfarpar arall sy'n cynhyrchu gwres.
  • Defnyddiwch atodiadau/ategolion a nodir gan y gwneuthurwr yn unig.
  • Cyfeirio pob gwasanaeth i bersonél gwasanaeth cymwys.

2.2 Diogelwch Trydanol

  • Sicrhewch y cyflenwad pŵer cyftage matches the requirements specified for the device.
  • Datgysylltwch y pŵer cyn gwneud unrhyw gysylltiadau neu wneud gwaith cynnal a chadw.
  • Avoid touching exposed wires or terminals when the unit is powered.
  • Mae sylfaen briodol yn hanfodol ar gyfer gweithrediad diogel.

3. Gosod

3.1 Dadbacio

Carefully remove the Night Ringer from its packaging. Inspect the unit for any signs of damage that may have occurred during shipping. If damage is found, contact your supplier immediately.

3.2 Mowntio

The BG-NR100 is designed for surface mounting. Use appropriate screws (not supplied) to secure the unit to a wall or other stable surface using the mounting tabs on either side of the enclosure. Ensure the mounting location allows for adequate ventilation and access to connections.

3.3 Gwifro Cysylltiadau

All connections are made via the screw terminal block located on the front of the unit. Ensure power is disconnected before making any wiring connections.

Label TerfynellDisgrifiadSwyddogaeth
TEL RING (T, R)Telephone Ring InputConnect to the tip (T) and ring (R) lines of a standard 90V telephone ring signal source.
CONTACT RING (A, B)External Contact Closure InputConnect to a dry contact closure (e.g., from a relay or switch) to trigger the ringer.
POWER SUPPLY (+24, -24)Mewnbwn PwerConnect to a regulated 24V DC power supply. Observe polarity (+24V to +24, -24V to -24).
BGM SOURCE (A, B)Mewnbwn Cerddoriaeth GefndirConnect the background music source here. The unit will mute this input during a ring event.
AMP INPUT (A, B)Amplifier Input / Output to Paging SystemConnect this output to the input of your paging amplifier or public address system. This carries the ringer tone and the muted BGM.

4. Gweithredu

4.1 Gweithrediad Sylfaenol

Once properly connected and powered, the BG-NR100 will automatically detect an incoming 90V telephone ring signal or a closure on the Contact Ring terminals. Upon detection, the unit will generate a dual-frequency electronic ringer tone and simultaneously mute any background music connected to the BGM Source input. The ringer tone will be sent to the Amp Input terminals for connection to your paging system.

4.2 Rheoli Cyfaint

The ringer volume can be adjusted using the TONE VOL knob located on the top left of the unit. Rotate the knob clockwise to increase the volume and counter-clockwise to decrease it. Adjust the volume to a suitable level for your environment.

5. cynnal

5.1 Glanhau

To clean the unit, wipe the exterior with a soft, dry cloth. Do not use liquid cleaners or aerosol cleaners. Ensure the unit is powered off and disconnected from all sources before cleaning.

5.2 Gofal Cyffredinol

The BG-NR100 is designed for reliable operation and requires minimal maintenance. Ensure it is installed in a location free from excessive dust, moisture, and extreme temperatures. Periodically check all wiring connections to ensure they are secure.

6. Datrys Problemau

If you experience issues with your Bogen BG-NR100 Night Ringer, refer to the following table for common problems and solutions.

ProblemAchos PosiblAteb
No ringer tone output.Dim pŵer i'r uned.Check power supply connections and ensure 24V DC is present.
Incorrect or no input signal (TEL RING or CONTACT RING).Verify 90V ring signal on TEL RING or proper contact closure on CONTACT RING.
Volume knob set too low.Adjust the TONE VOL knob clockwise.
Ringer tone is distorted or weak.Improper connection to paging ampllewywr.Sicrhau AMP INPUT is correctly connected to the amplifier input. Check ampgosodiadau lififier.
Background music does not mute.BGM SOURCE not connected correctly.Verify BGM SOURCE connections. Ensure the music source is routed through the Night Ringer.

If the problem persists after attempting these solutions, please contact Bogen technical support or a qualified service technician.

7. manylebau

Technical specifications for the Bogen BG-NR100 Night Ringer:

PriodoleddGwerth
GwneuthurwrBOGEN
BrandBogen
Rhif ModelBG-NR100
Pwysau Eitem1 pwys
Dimensiynau Cynnyrch1 x 5 x 3 modfedd
FCC Registration NumberCD23CH-17566-KX-N
Cyfwerthedd Ringer1.1 B
Dyddiad Ar Gael CyntafTachwedd 27, 2013

8. Gwarant a Chefnogaeth

8.1 Gwybodaeth Gwarant

For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Bogen website. Bogen Communications, Inc. typically provides a limited warranty against defects in materials and workmanship for a specified period from the date of purchase.

8.2 Cefnogaeth Dechnegol

If you require technical assistance or have questions regarding the installation or operation of your BG-NR100 Night Ringer, please contact Bogen technical support. Contact information can usually be found on the Bogen websafle neu yn y pecyn cynnyrch.

© 2024 Bogen Communications, Inc. Cedwir pob hawl.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.