Rhagymadrodd
This manual provides essential instructions for the safe and effective operation, setup, and maintenance of your Horizon SF-918 OCS-L Digital Hanging Scale. Please read this manual thoroughly before using the device to ensure proper function and to prevent damage or injury.

Image: The Horizon SF-918 OCS-L Digital Hanging Scale, showcasing its robust design with a top shackle and a lower weighing hook.
Gwybodaeth Diogelwch
- Do not exceed the maximum weight capacity of 300 kg (600 lbs). Overloading can damage the scale and pose a safety risk.
- Ensure the scale is securely suspended from a stable and appropriate support structure before attaching any load.
- Always stand clear of the load during weighing.
- Avoid dropping or subjecting the scale to severe impacts.
- Do not immerse the scale in water or expose it to excessive moisture. While durable, it is not waterproof.
- Cadwch allan o gyrraedd plant.
Cynnwys Pecyn
Gwiriwch fod yr holl eitemau yn bresennol yn y pecyn:
- Horizon SF-918 OCS-L Digital Hanging Scale
- Top Shackle (pre-attached)
- Bottom Weighing Hook
- 2 x Batris AAA

Image: The Horizon SF-918 OCS-L Digital Hanging Scale as packaged, showing the scale, hooks, and included AAA batteries.
Gosod
- Gosod Batri:
- Lleolwch y compartment batri ar gefn y raddfa.
- Agorwch y clawr batri.
- Mewnosodwch ddau (2) fatri AAA, gan sicrhau'r polaredd cywir (+/-).
- Close the battery cover securely. Ensure the batteries are firmly seated to prevent intermittent power loss during use.

Delwedd: Manwl view of the battery compartment, showing the correct placement of two AAA batteries.
- Attaching the Bottom Hook:
- The top shackle is typically pre-attached.
- Attach the provided bottom weighing hook to the lower attachment point of the scale. Ensure it is securely fastened.

Image: A close-up of the robust top shackle, indicating the secure attachment mechanism for suspending the scale.
Cyfarwyddiadau Gweithredu
The scale features a 1-inch illuminated LCD display and three control buttons: Power, HOLD/UNIT, and TARE.

Delwedd: Manwl view of the scale's digital display and control buttons, showing the current weight reading and unit.
- Pŵer ymlaen / i ffwrdd:
- Gwasgwch y Grym botwm (
) to turn the scale ON. The display will show "88888" then "0.0" with the current unit. - Pwyswch a dal y Grym button for 3 seconds to turn the scale OFF.
- Gwasgwch y Grym botwm (
- Unit Selection (Kg/Lb/N):
- With the scale ON and displaying "0.0", press the HOLD/UNIT button to cycle through the available weighing units: Kilograms (kg), Pounds (lb), and Newtons (N).
- Swyddogaeth Tare:
- To weigh items in a container, first hang the empty container on the hook.
- Gwasgwch y TARE button. The display will reset to "0.0".
- Add the items to be weighed into the container. The display will show the net weight of the items.
- Dal Swyddogaeth:
- While weighing a load, press the HOLD/UNIT button to lock the current weight reading on the display. The "HOLD" indicator will appear.
- Gwasgwch y HOLD/UNIT button again to release the hold function and return to live weighing.
- Note: This function holds the weight displayed at the moment the button is pressed, not necessarily the maximum weight achieved during the lift.
- Gweithdrefn Pwyso:
- Ensure the scale is ON and displaying "0.0" in your desired unit.
- Carefully attach the item to be weighed to the bottom hook.
- Allow the load to stabilize. The display will show the weight. The reading stable time is typically less than 10 seconds.
- Remove the load once the reading is taken.
- Pŵer Auto i ffwrdd:
- The scale will automatically turn off after approximately 3 minutes of inactivity to conserve battery life. This feature cannot be adjusted or disabled.
Cynnal a chadw
- Glanhau: Sychwch y raddfa gyda meddal, damp cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the finish and electronic components. Avoid getting water inside the unit.
- Storio: Store the scale in a dry, cool place away from direct sunlight and extreme temperatures. If storing for an extended period, remove the batteries to prevent leakage.
- Amnewid Batri: When the battery indicator appears on the display, replace both AAA batteries promptly to ensure accurate readings and proper operation.
Datrys problemau
- Nid yw'r raddfa yn troi ymlaen:
- Check battery installation. Ensure batteries are inserted with correct polarity and are fully charged. Replace batteries if necessary. Ensure battery contacts are clean and free from corrosion.
- Darlleniadau anghywir:
- Ensure the scale is suspended stably and not swinging. Verify the load is not touching any other surfaces. Check if the scale has been overloaded. Perform a tare operation before weighing.
- Scale turns off unexpectedly:
- This may be due to the 3-minute auto-off feature if no activity is detected. If it turns off during active weighing, check battery contact and ensure batteries are securely seated and not loose.
- Display shows "O-Ld" or similar:
- This indicates an overload condition. Remove the load immediately to prevent damage to the scale. Do not exceed the 300 kg / 600 lbs capacity.
Manylebau
| Nodwedd | Manyleb |
|---|---|
| Model | SF-918 OCS-L |
| Gallu | 300 kg / 600 pwys |
| Cywirdeb | 0.1 kg / 0.1 lb |
| Starting Weight | <200 g |
| Moddau Pwyso | Kilograms (kg), Pounds (lb), Newtons (N) |
| Arddangos | 1-inch Illuminated LCD |
| Auto Off | 3 munud o anactifedd |
| Ystod Tare | Capasiti llawn |
| Amser Sefydlog Darllen | <10 eiliad |
| Grym | 2 x Batris AAA (wedi'u cynnwys) |
| Dimensiynau (D x W x H) | 3.1 x 12 x 1.5 modfedd (bras) |
| Pwysau | 23 owns (1.37 pwys) |
| Deunydd | Alwminiwm Casing, Stainless Steel Load Receptor |
| Lliw | Coch |
Gwarant a Chefnogaeth
For warranty information or technical support, please refer to the contact details provided with your purchase or visit the official Horizon websafle. Cadwch eich derbynneb prynu fel prawf o brynu.