Microlife BP A200 AFIB

Microlife BP3MS1-4K Blood Pressure Monitor User Manual

Model: BP A200 AFIB

Rhagymadrodd

This user manual provides detailed instructions for the safe and effective operation of your Microlife BP3MS1-4K Blood Pressure Monitor. Please read this manual thoroughly before first use and keep it for future reference. This device is designed for accurate measurement of blood pressure and heartbeat at home.

Gwybodaeth Diogelwch

  • Consult your doctor before using this device if you have any medical conditions.
  • Peidiwch â defnyddio'r ddyfais ar fabanod, plant, nac unigolion sy'n methu â mynegi caniatâd.
  • Avoid taking measurements in a moving vehicle or during physical activity.
  • Cadwch y ddyfais a'i chydrannau allan o gyrraedd plant bach.
  • Use only original Microlife accessories and parts.

Cynnyrch Drosview

The Microlife BP3MS1-4K Blood Pressure Monitor is a comprehensive system for home blood pressure monitoring. It includes the main unit, an arm cuff, and necessary power accessories.

Microlife BP3MS1-4K Blood Pressure Monitor with carrying case, cuff, power adapter, and USB cable

Image: Complete set of the Microlife BP3MS1-4K Blood Pressure Monitor, including the main unit, a carrying case, an arm cuff, a power adapter, and a USB cable, laid out on a flat surface.

Yn agos view of the Microlife BP3MS1-4K Blood Pressure Monitor unit

Delwedd: Manwl view of the Microlife BP3MS1-4K Blood Pressure Monitor unit, highlighting its display screen and control buttons.

The device features an XL-Display for easy reading of measurements and includes a USB port for data transfer.

Gosod

1. Cyflenwad Pŵer

The Microlife BP3MS1-4K can be powered by batteries or an AC adapter.

  • Gosod Batri: Open the battery compartment on the back of the device. Insert the required batteries, ensuring correct polarity (+/-). Close the compartment. A low battery indicator will appear on the display when batteries need replacement.
  • Cysylltiad addasydd AC: Connect the AC adapter to the device's power input jack and then plug it into a wall outlet.

2. Cysylltiad Cyff

Insert the air tube connector of the cuff firmly into the air jack on the side of the monitor unit.

3. Gosod Dyddiad ac Amser

Refer to the device's on-screen prompts or specific button combinations (usually involving the 'M' or 'Set' button) to set the current date and time. This ensures accurate time-stamping for stored measurements.

Cyfarwyddiadau Gweithredu

1. Paratoi ar gyfer Mesur

  • Osgowch fwyta, ysmygu, neu ymarfer corff am o leiaf 30 munud cyn mesur.
  • Rest for 5-10 minutes in a quiet environment before taking a reading.
  • Eisteddwch yn unionsyth gyda'ch cefn wedi'i gynnal, eich traed yn wastad ar y llawr, a'ch coesau heb eu croesi.
  • Rhowch eich braich ar fwrdd fel bod y cyff ar lefel y galon.

2. Cymhwyso'r Cyff

Wrap the cuff around your bare upper arm, approximately 2-3 cm above the elbow joint. Ensure the air tube runs down the center of your arm. The cuff should be snug but not too tight.

3. Taking a Measurement (MAM Technology)

The device features MAM (Microlife Average Mode) technology, which automatically takes three measurements in quick succession and calculates an average for a more reliable result.

  • Gwasgwch y YMLAEN / I FFWRDD botwm i ddechrau'r mesuriad.
  • The cuff will inflate, and the device will automatically take three consecutive readings with a short pause between each.
  • After the third measurement, the average systolic, diastolic, and pulse readings will be displayed on the XL-Display.
Microlife BP3MS1-4K Blood Pressure Monitor display showing readings

Image: The display of the Microlife BP3MS1-4K Blood Pressure Monitor showing a time of 12:15, systolic pressure of 129 mmHg, diastolic pressure of 78 mmHg, and a pulse rate of 65 beats per minute.

4. Swyddogaeth Cof

The device stores up to 200 measurements. To review past readings, press the M (Memory) button. Each press will cycle through the stored measurements.

5. Cysylltedd USB

The integrated USB port allows for data transfer to a computer for analysis and tracking. Refer to the Microlife software instructions for detailed steps on connecting and downloading data.

Cynnal a chadw

Glanhau

  • Glanhewch yr uned fonitro a'r cyff gyda lliain meddal, sych.
  • Os oes angen, defnyddiwch frethyn yn ysgafnampwedi'i lanhau â dŵr neu lanhawr ysgafn, nad yw'n sgraffiniol.
  • Do not use harsh chemicals, abrasive cleaners, or immerse the device in water.

Storio

  • Store the device in its carrying case in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Os nad ydynt yn cael eu defnyddio am gyfnod hir, tynnwch y batris i atal gollyngiadau.

Datrys problemau

ProblemAchos PosiblAteb
Nid yw dyfais yn troi ymlaen.Low or dead batteries; incorrect battery insertion; power adapter issue.Replace batteries; check battery polarity; ensure power adapter is securely connected.
Neges gwall ar yr arddangosfa.Cuff not applied correctly; excessive movement during measurement; irregular heartbeat detected.Reapply cuff correctly; remain still and quiet; consult a doctor if irregular heartbeat persists.
Darlleniadau anghywir.Improper cuff size; incorrect measurement posture; recent physical activity.Ensure correct cuff size for your arm; follow preparation guidelines; rest before measurement.
No data transfer via USB.Incorrect cable connection; software not installed or running.Check USB cable connection; install Microlife software and ensure it is running.

If problems persist, contact Microlife customer support.

Manylebau

Microlife BP3MS1-4K Blood Pressure Monitor with dimensions indicated

Image: The Microlife BP3MS1-4K Blood Pressure Monitor unit with measurement lines indicating its dimensions, approximately 15 cm (6.3 inches) in height.

NodweddManylyn
Rhif ModelBP A200 AFIB
Dimensiynau Cynnyrch15.2 x 4.2 x 9.2 cm
Pwysau Eitem393 g
Dull MesurOsgilometrig
Cof200 o fesuriadau
ArddangosXL-Display
Nodweddion ArbennigMAM technology (3 automatic measurements), Clinically tested (BHS protocol), USB port, Low battery indicator
Ffynhonnell PwerWedi'i Bweru â Batri
Cydrannau wedi'u Cynnwyscyff

Gwarant a Chefnogaeth

Microlife products are manufactured to the highest quality standards. For information regarding warranty coverage, technical support, or service, please refer to the warranty card included with your product or visit the official Microlife websafle. Cadwch eich derbynneb prynu fel prawf o brynu ar gyfer hawliadau gwarant.

© 2024 Microlife. Cedwir pob hawl.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.