1. Rhagymadrodd
The VOLTCRAFT PH-100 ATC is a precision pH-meter designed for accurate measurement of pH levels in various liquids. This device is suitable for applications in swimming pools, aquariums, laboratories, and educational settings. It features Automatic Temperature Compensation (ATC) to ensure reliable readings across different temperatures and a HOLD function for convenient data recording.
2. Nodweddion Cynnyrch
- Ystod Mesur: 0 i 14 pH
- Penderfyniad: 0.01 pH for precise readings
- Iawndal Tymheredd Awtomatig (ATC): Ensures accurate measurements regardless of sample tymheredd.
- Dal Swyddogaeth: Freezes the current reading on the large LCD display for easy viewing.
- Amser Ymateb Cyflym: Provides quick measurement results.
- Defnydd Pŵer Isel: Yn ymestyn oes y batri.
- Arddangosfa LCD fawr: Clear and easy-to-read digital output.
3. Gwybodaeth Diogelwch
Darllenwch a deallwch yr holl gyfarwyddiadau diogelwch cyn defnyddio'r ddyfais. Gall methu â gwneud hynny arwain at anaf neu ddifrod i'r cynnyrch.
- Cadwch y ddyfais allan o gyrraedd plant.
- Do not immerse the main meter unit in water or other liquids. The pH probe is designed for immersion, but the main unit is not waterproof.
- Handle the pH electrode with care. It is a delicate component.
- Peidiwch â cheisio agor na newid y ddyfais. Cyfeiriwch yr holl waith cynnal a chadw at bersonél cymwys.
- Cael gwared ar fatris yn unol â rheoliadau lleol.
4. Cynnwys Pecyn
Gwiriwch fod yr holl eitemau yn bresennol yn y pecyn:
- VOLTCRAFT PH-100 ATC pH-Meter Unit
- pH Electrode Probe
- Llawlyfr Defnyddiwr (y ddogfen hon)
- Note: 3 AAA batteries are required for operation and may not be included.
5. Gosod
5.1. Gosod Batri
- Lleolwch glawr adran y batri ar gefn y mesurydd.
- Slide or unscrew the cover to open the compartment.
- Mewnosodwch 3 fatri AAA, gan sicrhau'r polaredd cywir (+/-).
- Amnewid y clawr adran batri yn ddiogel.
5.2. Connecting the pH Probe
- Carefully remove the protective cap from the pH electrode probe.
- Connect the BNC connector of the pH probe to the corresponding port on the top of the meter unit. Twist gently until it is secure.
- Ensure the connection is firm to prevent signal interference.

Image: The VOLTCRAFT PH-100 ATC pH-meter with its probe connected, displaying a pH reading.
6. Gweithrediad
6.1. Pweru Ymlaen / I ffwrdd
- I droi’r mesurydd ymlaen, pwyswch y ON botwm.
- To power off the meter, press the ODDI AR botwm.
6.2. Cymryd Mesur
- Ensure the meter is powered on and the probe is connected.
- Rinse the pH electrode with distilled water before each measurement.
- Immerse the pH electrode into the sample solution, ensuring the bulb is fully submerged.
- Gently stir the solution and wait for the reading on the LCD display to stabilize.
- Record the stable pH value.
6.3. Using the HOLD Function
- Yn ystod mesuriad, pwyswch y DALWCH botwm i rewi'r darlleniad cyfredol ar yr arddangosfa.
- Gwasgwch y DALWCH botwm eto i ryddhau'r darlleniad a dychwelyd i fesuriad byw.
7. graddnodi
Regular calibration is essential for maintaining the accuracy of your pH-meter. It is recommended to calibrate the device before initial use and periodically thereafter, especially if precise measurements are critical or if the meter has been stored for an extended period.
7.1. Calibration Procedure (General Guidelines)
The VOLTCRAFT PH-100 ATC typically requires a two-point calibration using standard buffer solutions. Refer to the specific calibration instructions provided with your buffer solutions or on the device itself for detailed steps. Generally, the process involves:
- Prepare two standard pH buffer solutions, commonly pH 7.00 and either pH 4.00 or pH 10.00, depending on your expected measurement range.
- Rinse the pH electrode with distilled water.
- Immerse the electrode into the first buffer solution (e.g., pH 7.00).
- Follow the meter's calibration mode instructions (usually involving pressing a CAL button and adjusting the reading to match the buffer value).
- Rinsiwch yr electrod â dŵr distyll.
- Immerse the electrode into the second buffer solution (e.g., pH 4.00 or pH 10.00).
- Repeat the calibration adjustment for the second buffer.
- Rinse the electrode again with distilled water after calibration.
Note: Buffer solutions are not typically included with the meter and must be purchased separately.
8. cynnal
8.1. Electrode Care and Cleaning
- Always rinse the pH electrode with distilled or deionized water before and after each use.
- Store the electrode with its protective cap filled with a suitable storage solution (e.g., pH 4 buffer or electrode storage solution). Never store dry.
- If the electrode becomes dirty or readings are sluggish, clean it gently according to the electrode manufacturer's instructions. Avoid abrasive cleaning.
8.2. Storio
- When not in use, store the meter and probe in a cool, dry place, away from direct sunlight and extreme temperatures.
- Tynnwch y batris os na fydd y ddyfais yn cael ei defnyddio am gyfnod hir er mwyn atal gollyngiadau.
9. Datrys Problemau
If you encounter issues with your VOLTCRAFT PH-100 ATC, refer to the following common problems and solutions:
| Problem | Achos Posibl | Ateb |
|---|---|---|
| Nid yw'r mesurydd yn troi ymlaen. | Batris marw neu wedi'u gosod yn anghywir. | Check battery polarity; replace with new AAA batteries. |
| Inaccurate or unstable readings. |
|
|
| Slow response time. | Electrode is old or contaminated. | Clean the electrode. If the problem persists, the electrode may need replacement. |
10. manylebau
| Paramedr | Gwerth |
|---|---|
| Rhif Model | PH-100 ATC (YK-21PH W/ PE-03) |
| Brand | VOLTCRAFT |
| Ystod Mesur | 0 - 14 pH |
| Datrysiad | 0.01 pH |
| Iawndal Tymheredd Awtomatig (ATC) | Oes |
| Ffynhonnell Pwer | 3 x batris AAA |
| Dimensiynau Cynnyrch (L x W x H) | 20.5 x 6.8 x 3 cm |
| Pwysau Eitem | 220 gram |
| Lleithder Gweithredu | 50-80% |
| Upper Temperature Range | Graddau 30 Celsius |
| Cywirdeb Tymheredd | 1°C |
11. Gwarant a Chefnogaeth
This VOLTCRAFT product comes with a minimum Gwarant 2 mlynedd o'r dyddiad prynu. Mae'r warant hon yn cwmpasu diffygion mewn deunyddiau a chrefftwaith o dan ddefnydd arferol.
For technical support, warranty claims, or service inquiries, please contact your retailer or the VOLTCRAFT customer service department. Keep your proof of purchase for warranty validation.