Cooper-Atkins SRH77A-ONLY-E

Cooper-Atkins SRH77A-ONLY-E 1 and 2 Zone Temperature/Humidity Thermistor Instrument User Manual

Model: SRH77A-ONLY-E

Rhagymadrodd

This manual provides detailed instructions for the proper use and maintenance of your Cooper-Atkins SRH77A-ONLY-E Thermistor Instrument. This device is designed for accurate temperature and humidity measurements across one or two zones, featuring a backlight display, sealed keypad, and Min/Max memory functions. Please read this manual thoroughly before operating the instrument.

Gwybodaeth Diogelwch

Observe the following safety precautions to ensure safe operation and to prevent damage to the instrument:

  • This unit is not waterproof. Do not immerse it in water.
  • If the unit becomes wet inside due to cleaning, rain, or condensation, unreliable readings may occur.
  • Do not use the instrument for purposes other than its intended use as a temperature and humidity measurement device.
  • Replace the battery promptly when the 'LO P' indicator appears to ensure accurate readings.

Cynnyrch Drosview

The Cooper-Atkins SRH77A-ONLY-E is a versatile thermistor instrument designed for precise temperature and humidity monitoring. Key features include:

  • Arddangosfa Olau Cefn: For improved visibility in low-light conditions.
  • Sealed Keypad: Protects the instrument from spills and dust.
  • Min/Max Memory: Records the minimum and maximum readings.
  • Diffodd Auto: Conserves battery life after 15 minutes of non-use or continuous ON mode.
  • Gwahaniaeth tymheredd: Measures the difference between two temperature probes.
  • %RH and Wet Bulb: Provides relative humidity and wet bulb temperature readings.
  • Battery Eliminator Jack: Allows for external power supply (adapter not included).
Cooper-Atkins SRH77A-ONLY-E Thermistor Instrument in its protective blue case, open to show the digital display and control buttons.

Image: The SRH77A-ONLY-E instrument displayed within its protective blue case, showing the digital screen, control buttons, and internal instructions.

Gosod

1. Gosod Batri

  • The instrument requires one 9-volt NEDA 1604 or equivalent alkaline battery.
  • Agorwch y compartment batri sydd wedi'i leoli ar gefn yr uned.
  • Connect the 9-volt battery to the battery clip, observing correct polarity.
  • Rhowch y batri yn y compartment a chau'r clawr yn ddiogel.

2. Cysylltiad y chwiliedydd

  • For temperature measurements, insert the thermistor probe(s) into the T1 and/or T2 jacks.
  • For humidity measurements, insert the humidity probe into the T3 jack.

Cyfarwyddiadau Gweithredu

1. Pŵer Ymlaen / I ffwrdd

  • I droi'r uned ON, gwasgwch y YMLAEN / I FFWRDD botwm.
  • I droi'r uned ODDI AR, gwasgu a dal y YMLAEN / I FFWRDD botwm am 3 eiliad.

2. Mesur Tymheredd

  • Ensure a temperature probe is inserted into the T1 or T2 jack.
  • Gwasgwch y TEMP 1 or TEMP 2 button to display the temperature reading for the respective zone.
  • The display will show the current temperature. If no probe is connected, the display will show '----'.

3. Humidity Measurement

  • Ensure a humidity probe is inserted into the T3 jack.
  • Gwasgwch y RH button to display the relative humidity (%RH) reading.

4. Min/Max Memory

  • Gwasgwch y MIN / MAX button to display the minimum and maximum recorded readings.
  • Gwasgwch y MIN / MAX button again to clear the memory and reset for new readings.

5. Temperature Differential

  • With probes in T1 and T2, press the DIFF button to display the temperature difference between probe T1 and T2.

6. Wet Bulb Temperature

  • With a humidity probe in T3, press the BWLB GWLYB button to display the calculated wet bulb temperature.

7. Golau cefn

  • Gwasgwch y LIGHT/DC button to illuminate the display backlight.
  • To turn the backlight off, press the LIGHT/DC botwm dair gwaith o fewn 5 eiliad.

Cynnal a chadw

  • To clean the instrument, wipe the exterior with a damp lliain. Peidiwch â defnyddio glanhawyr sgraffiniol na throchi'r uned mewn dŵr.
  • Store the instrument in a dry environment when not in use.
  • Replace the 9-volt battery when the 'LO P' indicator appears on the display to ensure continued accuracy.

Datrys problemau

MaterAchos / Ateb Posibl
'LO P' displayedLow battery power. Replace the 9-volt NEDA 1604 or equivalent alkaline battery.
'HI P' displayedHigh battery power. This is less common but indicates a power issue. Ensure correct battery type and installation.
Temperature reading shows '----' or is inaccurate
  • Probe not properly connected to the T1/T2 jack.
  • Temperature being monitored is outside the instrument's range (-40°F to 300°F).
  • Probe is damaged or faulty.
  • Unit may have been exposed to moisture internally.
Humidity reading shows '----' or is inaccurate
  • Humidity probe not properly connected to the T3 jack.
  • Humidity being monitored is above 95% RH.
  • Humidity probe is damaged or faulty.
  • Unit may have been exposed to moisture internally.
Nid yw'r uned yn troi ymlaenBattery is dead or incorrectly installed. Check battery and replace if necessary.

Manylebau

NodweddManyleb
Rhif ModelSRH77A-ONLY-E
Amrediad Tymheredd-40°F i 300°F (-40°C i 150°C)
Ystod Mesur Lleithder10 to 95% RH (30 to 130°F / 1 to 54°C)
Ffynhonnell Pwer9-volt Battery Powered
Math ArddangosDigidol
Deunydd AllanolPlastig
Dimensiynau Pecyn9.41 x 8.03 x 3.54 modfedd
Pwysau1.1 Bunt

Gwarant a Chefnogaeth

Cooper-Atkins Corporation warrants this instrument to be free from defects in materials and workmanship for a specified period from the date of purchase. For specific warranty details, technical support, or service inquiries, please contact Cooper-Atkins customer service directly. Keep your proof of purchase for warranty claims.

For further assistance, please visit the official Cooper-Atkins websafle neu cysylltwch â'u cymorth cwsmeriaid.

© 2023 Cooper-Atkins Corporation. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.