MSA 815369

MSA 815369 Advantage Low Profile P100 Respirator Cartridges User Manual

Model: 815369

1. Rhagymadrodd

This manual provides essential information for the proper use, installation, and maintenance of the MSA 815369 Advantage Low Profile P100 Respirator Cartridges. Please read these instructions carefully before using the product to ensure safety and optimal performance. These cartridges are designed for particulate filtration and are intended for use with compatible MSA Advantage series respirators.

2. Cynnyrch Drosview

MSA 815369 Advantage Low Profile P100 Respirator Cartridges

Image showing the MSA 815369 Advantage Low Profile P100 Respirator Cartridges.

Enw Cynnyrch: MSA 815369 Advantage Low Profile P100 Respirator Cartridges

Disgrifiad: Isel profile P100 particulate filter cartridges, supplied in a package of two.

Nodweddion Allweddol: P100 particulate filtration efficiency, low profile design for improved visibility.

Deunydd: Polypropylen (PP)

Lliw: Llwyd Ysgafn

Maint: Approximately 1 inch diameter by 1 inch length

Cydnawsedd: These cartridges are compatible only with MSA Advantage 200 LS, 420 Half-Mask, and 1000, 3000, and 4000 Series Full-Facepiece Respirators. Ensure your respirator model is listed for proper fit and function.

3. Gwybodaeth Diogelwch

  • Rhybudd Cynnig 65: Gall y cynnyrch hwn eich amlygu i gemegau y gwyddys gan Talaith California eu bod yn achosi canser neu namau geni neu niwed atgenhedlu arall.
  • Pwysig: Do not use these cartridges with gas or vapor cartridges. They are designed exclusively for particulate filtration.
  • Always perform a user seal check according to your respirator's instructions before entering a contaminated area.
  • Do not use in atmospheres containing less than 19.5% oxygen.
  • Do not use when concentrations of contaminants are immediately dangerous to life or health (IDLH).
  • Consult local regulations and safety guidelines for proper use and disposal.

4. Gosod a Gosod

Follow these steps to properly install the MSA 815369 Advantage Low Profile P100 Respirator Cartridges onto your compatible MSA Advantage series respirator:

  1. Align the Cartridge: Position the cartridge so that its connection point aligns with the filter holder on your respirator.
  2. Attach the Cartridge: Push the cartridge firmly into the holder. While pushing, twist the cartridge clockwise until it locks securely into place. A distinct click or firm stop should indicate proper seating.
  3. Gwirio Sêl: After installation, perform a positive and/or negative pressure user seal check as described in your respirator's instruction manual to ensure a proper seal.

5. Cyfarwyddiadau Gweithredu

Once the cartridges are correctly installed and a proper seal is verified, the respirator system is ready for use. These P100 cartridges provide a high level of protection against all particulate aerosols, including oil-based and non-oil-based particulates.

  • Always ensure the respirator is properly fitted and sealed to your face before entering any hazardous environment.
  • Do not use these cartridges for protection against gases or vapors.
  • Leave the contaminated area immediately if breathing becomes difficult, dizziness or other distress occurs, or if you smell or taste contaminants.

6. cynnal

Proper maintenance ensures the continued effectiveness and safety of your respirator cartridges.

  • Tynnu cetris: To remove a cartridge, twist it counterclockwise and pull it out from the respirator's filter holder.
  • Amlder Amnewid: Replace the cartridge every 40 hours of use, or sooner if breathing resistance increases significantly, or if physical damage to the cartridge is observed. Always refer to the manufacturer's guidelines for your specific respirator model for precise replacement schedules.
  • Storio: Store unused cartridges in their original sealed packaging in a cool, dry place away from contaminants and direct sunlight.
  • Gwaredu: Dispose of used cartridges according to local regulations for hazardous waste, as they may contain captured contaminants.

7. Datrys Problemau

If you encounter issues with your MSA 815369 Advantage Low Profile P100 Respirator Cartridges, consider the following:

  • Anhawster Anadlu: If breathing becomes difficult, the cartridges may be clogged with particulates. Replace them immediately.
  • Sêl Wael: If a proper seal cannot be achieved during a user seal check, re-install the cartridges, adjust the respirator fit, or inspect the respirator facepiece for damage.
  • Cartridge Not Locking: Ensure the cartridge is correctly aligned with the filter holder and twist firmly until it locks. Do not force it. If it still doesn't lock, inspect both the cartridge and the respirator's holder for damage.

For issues not resolved by these steps, contact MSA customer support.

8. manylebau

Priodoledd Manylyn
Brand MSA
Enw Model 815369
Deunydd Polypropylen (PP)
Lliw Llwyd Ysgafn
Maint (Dimensiynau) 1 x 1 x 1 modfedd (bras)
Pwysau Eitem 0.07 Bunt
Cydrannau wedi'u Cynnwys Hidlo
Cyfrif Uned 2.0 Count (per package)
GTIN / UPC 094700673145

9. Gwarant a Chefnogaeth

For specific warranty information regarding the MSA 815369 Advantage Low Profile P100 Respirator Cartridges, please refer to the documentation provided with your original respirator purchase or visit the official MSA website. For technical support, product inquiries, or assistance with troubleshooting, please contact MSA customer service directly.

You can typically find contact information on the MSA official websafle: www.msafety.com

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.